The primary pan is totally dry no condensation water.
Ac unit in attic leaking.
As soon as you discover a leak be sure to turn off your air conditioner.
If water is dripping from your ceiling and your furnace and or air handler is located in the attic the most likely cause is a clogged condensate drain line.
The ac compressor is leaking water.
It can potentially cause extensive and expensive water damage.
Any leaking or pooling water around an indoor ac unit should be attended to right away.
A powerful wet dry vac and proper hose attachment can take care of most jobs.
Please make sure all ductwork is insulated.
The drain pipe is clogged a clogged drain pipe is the most common cause of standing water in the drain pan.
Unscrew the cap and pour about six ounces of vinegar down the drain line.
Ensure that the central ac system is installed using a secondary drain line more so if the unit is in the attic.
If the metal anywhere on the ductwork is exposed to ambient air from the hot attic then it will cause the ductwork to sweat leak and cause damage in your attic.
A clog in the drain line of an attic ac unit is a homeowner s worst nightmare.
One common culprit of freon leaks is the improper installation of your air conditioning unit.
Any ductwork that is installed in an attic must be either wrapped with insulation or you must use flex duct which is already insulated.
It should have a piece of pipe sticking up at a 90 degree angle.
The following tips can be used for reducing the chances of water damages.
This humidity is left behind in the form of condensation on the coils.
Poor soldering is usually to blame as freon can escape through improperly sealed areas.
This can help prevent the water from causing damage to the electrical components of your air conditioner and limit the amount of water damage to your home.
As air passes over the evaporator coils in your air conditioner it cools down and loses some of its humidity.
So what is causing the water leak.
Have drain pan shutoff switch installed and equip it with a float.
Another potential cause of a freon leaking air conditioner unit is any kind of physical damage.
With these systems condensate leaks can lead to a mess but it s nothing compared to a condensate leak that occurs at an air conditioner in an attic or really any place that has finished space.
Therefore your ceiling leak may appear to be originating from your furnace when it is actually coming from the air handler or indoor air conditioning unit.
Ensure ac unit is installed with a safety.
The indoor ac unit in many phoenix area homes is attached to your furnace and located in the attic.
You can call a professional or try to do it yourself.
Locate the pvc pipe near your air handler s drain pan.